  Datasheet File OCR Text:
 Filename: TFS246H4.doc
version 1.3
16.05.2002
VI TELEFILTER
Measurement condition
Ambient temperature: Input power level: Terminating impedances Input: Output: External coil: 23 0 *) 490 490 270 C dBm || -2.62 pF || -2.62 pF nH
Filter Specification
TFS 246 H4
1/5
Characteristics
Remark:
Reference level for the relative attenuation arel of the TFS246H4 is the minimum of the pass band attenuation amin. The minimum of the pass band attenuation amin is defined as the insertion loss ae. The centre frequency fc is the arithmetic mean value of the upper and lower frequencies at the 3 dB filter attenuation level relative to the insertion loss ae. The nominal frequency fN is fixed at 246 MHz without any tolerance. The given values for the relative attenuation arel and for the group delay ripple have to be reached at the frequencies given below even if the centre frequency fc is shifted due to the temperature coefficient of frequency TCf in the operating temperature range and due to a production tolerance for the centre frequency fc.
Data
Insertion loss (Reference level) Nominal frequency Pass band ripple fN - 85 kHz ... fN + 93 kHz Relative attenuation fN fN 330 kHz ... fN 400 kHz ... fN 600 kHz ... fN 800 kHz ... fN 1,6 MHz ... fN 3,0 MHz ... fN 20 MHz ...
arel ae = amin fN
typ. value
2,5 0,5 120 400 600 800 1,6 3,0 20 100 kHz kHz kHz MHz MHz MHz MHz MHz 1,5 22 33 41 47...55 52...55 54 55...70 0,5 0,8 1,2 TCf **)
tolerance / limit
max 5 dB
dB
246,000 MHz dB dB dB dB dB dB dB dB dB s s s max max min min min min min min min max max max 1,5 3 18 25 40 45 45 46 45 1,2 1,5 2,5 dB dB dB dB dB dB dB dB dB s s s
fN fN fN fN fN fN fN fN
Group delay distortion fN 50 kHz fN 70 kHz fN 100 kHz
GDD
Operating temperature range Storage temperature range Temperature coefficient of frequency Frequency inversion temperature T0
- 25 C ... + 85 C - 30 C ... + 85 C -
- 0,036 ppm/K + 25 C
*) The terminating impedances depend on parasitics and q-values of matching elements and the board used, and are to be understood as reference values only. Should there be additional questions do not hesitate to ask for an application note or contact our design team. **) f(Hz) = TCf(ppm/ K) x (T-T0) x fTo(MHz)
Generated: Checked / approved:
VI TELEFILTER Vectron International, Inc. Potsdamer Strae 18 267 Lowell Road D 14 513 TELTOW / Germany Hudson, NH 03051 / USA Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: vti@vtinh.com E-Mail: tft@telefilter.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: TFS246H4.doc
version 1.3
16.05.2002
VI TELEFILTER
Construction and pin configuration
(All dimensions in mm)
Filter Specification
TFS 246 H4
2/5
S 246 H4 P16
1 3
7,2 Ma x. 2,54+-0,2
2 Ma x.
Datecode M N P ...
Year + week 2000 2001 2002
1 7 3,4 2,5,6,8,9,10,11,12
Input Output External coil Ground
2,54 +-0,2
0,8
50 Ohm Test circuit 1
L1
1 7
5,2 Ma x.
L2
C1
SAW
3
4
L3
2,5,6,8,9,10,11,12
C2
50 Ohm Test circuit 2
C1 1 7 C2
L1
SAW
3
4
L3
2,5,6,8,9,10,11,12
L2
VI TELEFILTER Vectron International, Inc. Potsdamer Strae 18 267 Lowell Road D 14 513 TELTOW / Germany Hudson, NH 03051 / USA Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: vti@vtinh.com E-Mail: tft@telefilter.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: TFS246H4.doc
version 1.3
16.05.2002
VI TELEFILTER
Stability characteristics
Filter Specification
TFS 246 H4
3/5
After the following tests the filter shall meet the whole specification: 1. Shock: 2. Vibration: 3. Change of temperature: 500g, 18 ms, half sine wave, 3 shocks each plane; DIN IEC 68 T2 - 27 10 Hz to 500 Hz, 0,35 mm or 5g respectively, 1 octave per min, 10 cycles per plan, 3 plans; DIN IEC 68 T2 - 6 -55 C to 125C / 30 min. each / 10 cycles DIN IEC 68 part 2 - 14 Test N
4. Resistance to solder heat (reflow): reflow possible: twice max.; for temperature conditions, please refer to the attached "Air reflow temperature conditions" on page 4;
Packing
Tape & Reel: IEC 286 - 3, with exception of value for N and minimum bending radius; tape type II, embossed carrier tape with top cover tape on the upper side; max. pieces of filters per reel: Reel of empty components at start: Reel of empty components at start including leader: Trailer
Tape (all dimensions in mm) W Po Do E F P2 P1 Ao Bo : : : : : : : : : 16 4 0,3 0,1
Do Po
3000 min 300 mm min 500 mm min 300 mm
EMBOSSED CARRIER TAPE
P2
1,5 + 0,1 1,75 0,1 7,5 0,1 0,6 2 8 1,5 5,5 7,5 0,1 0,1
COVER TAPE P1 Ao D1
E
G (min) :
F W
0,1 0,1
13,4
0,1
Bo
D1(min) :
G
W2
Reel (all dimensions in mm): A W1 N (min) C : : : W2 (max) : : 330 16,4 +2 22,4 50 13 + 0,5 / - 0,2
A C N
W1
The minimum bending radius is 45 mm. The mounting surface of the filters faces the bottom side of the embossed carrier tape. Markings on the filters can be read if the upper side of the carrier tape is regarded with the sprocket holes on its right.
VI TELEFILTER Vectron International, Inc. Potsdamer Strae 18 267 Lowell Road D 14 513 TELTOW / Germany Hudson, NH 03051 / USA Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: vti@vtinh.com E-Mail: tft@telefilter.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: TFS246H4.doc
version 1.3
16.05.2002
VI TELEFILTER
Air reflow temperature conditions
Filter Specification
TFS 246 H4
4/5
1st and 2nd air reflow profile
Name: Temperature: Time: pre-heating periods 150 C - 170 C 60 sec. - 90 sec. main-heating periods over 200 C 20 sec. - 25 sec. peak temperature 255 C 5 C
Chip-mount air reflow profile
260 240 220 200 180 temperature / C 160 140 120 100 80 60 40 20 0 0 20 40 60 80 100 120 time / sec. 140 160 180 200 220 240
Table for temperature vs. time during the air reflow process Tolerance of temperatures: 5 C time / sec. 0 10 20 30 40 50 60 70 80 90 100 110 120 130 temperature / C 23 34 46 60 80 103 121 134 143 150 154 156 158 159 time / sec. 140 150 160 170 180 190 195 200 205 210 215 220 230 240 temperature / C 160 161 164 170 180 205 230 255 230 205 180 165 140 120
VI TELEFILTER Vectron International, Inc. Potsdamer Strae 18 267 Lowell Road D 14 513 TELTOW / Germany Hudson, NH 03051 / USA Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: vti@vtinh.com E-Mail: tft@telefilter.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: TFS246H4.doc
version 1.3
16.05.2002
VI TELEFILTER
History
Version 1.0 1.1 1.2 1.3 Reason of Changes
Filter Specification
TFS 246 H4
5/5
Name Dr. Wall Dr. Wall Dr. Wall Dr. Wall
Date 07.02.2002 27.03.2002 19.04.2002 16.05.2002
Generate specification according to customer's requirements Add and correct typical data. Correct value for coupling coil. Change operating temperature range from -20C ... 85C to -25C ... 85C Correct typo for first selection value (from 8 to 18 dB)
VI TELEFILTER Vectron International, Inc. Potsdamer Strae 18 267 Lowell Road D 14 513 TELTOW / Germany Hudson, NH 03051 / USA Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: vti@vtinh.com E-Mail: tft@telefilter.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.


▲Up To Search▲   

 
Price & Availability of TFS246H4

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X